@ -0,0 +1,42 @@ |
|||
== Vario Module == |
|||
|
|||
- Pressing the "v" (down) button cycles between displays as follows: |
|||
|
|||
* vario (in m/s) |
|||
Displays a signed fractional value representing the ascent or |
|||
descent speed in meters per second. |
|||
|
|||
* vario (in Pascal) |
|||
Displays a signed integer value representing the ascent or |
|||
descent speed in Pascal/second. |
|||
|
|||
* pressure (in hPa) |
|||
Displays a signed fraction representing the pressure measured at |
|||
the current altitude. |
|||
|
|||
* max Vz (in m/s) |
|||
Displays the maximum vertical speed in meters/second. |
|||
|
|||
* min Vz (in m/s) |
|||
Displays the minimum vertical speed in meters/second. |
|||
|
|||
- A long press on the "#" button performs a context sensitive function: |
|||
|
|||
* during vario display, changes the vario sound mode: |
|||
Off (default, no symbol displayed) |
|||
Ascent 0 (start beeping at 0.0m/s, beeper1 and beeper2 symbols |
|||
displayed) |
|||
Ascent 1 (start beeping at 0.1m/s, beeper1 symbol displayed) |
|||
Both (beep for up or down, beeper1 and beeper2 symbols |
|||
displayed) |
|||
|
|||
Tone frequency, number and duration of beeps depend on climb rate. |
|||
|
|||
* during max/min Vz display, resets both the max and min values. |
|||
|
|||
- The "record" icon is flashed at one second intervals, indicating that |
|||
the watch is in vario mode and receiving pressure measurements. |
|||
|
|||
Note that the upper line must be in altimeter mode for the vario to |
|||
work, as it relies on updates from the altimeter. If the altimeter |
|||
is not active, the vario display shows "noAlt". |